the GENUINE!
The ready for use MARSHALL temperature sensor is a combination of a high temperature resistant steel tube, covered with a thin graphite coating and assembled with a thermo wire. The element can be used directly and without pre-heating.
  Class 1 type K (NiCr-Ni) Marshall thermocouples with ceramic insulators, green-white sleeves (according to international colour code for type K) and U-clip.

(see table of all sizes)
A Marshall thermo-element consists of a chromium-steel tube type SS 446 / DIN 1.4749 and two type K (NiCr/Ni) thermo wires. These elements are simple to connect, very economical and easy to use with the lightweight lance and optional digital pyrometer.
  small tip at the hot end for quick response
The hot junction is welded into a small diameter tip. Because of the wall thickness of only 3 mm at this sensible point, very quick temperature readings can be made. The solid construction of the assembly guaranties a very good service life. Through this combination of quick response, long service life and low price MARSHALL became the very well reputed market-leader he is today, the best in his class and reported to be superior.
  Marshall thermokoppels met "Fluke" digitale meter en houder
The advantages of MARSHALL elements are:
  • extremely low costs per temperature reading
  • can be used up to 1350º C
  • quick response time due to the thin wall at the hot tip
  • several hundred measurements in aluminium, excellent durability in bronze, brass and copper (-alloys)
  • easy to use and lightweight design
  • excellent resistance to chemical corrosion of molten aluminium and copper (alloys)
  • Standard type K class 1 elements according to European standard IEC-584. Upon request all elements can be furnished with a certificate of conformity.
    All accessories, such as grips, lances and pyrometers are available from stock.

    Application: Aluminium- and copper (alloys), dip measurements and continuoustemperature sensing for primary aluminium and copper, introughs, (crucible-) furnaces, filter-boxes and many more
    Max. temperature: 1300 - 1350° C for dip measurements
    850° C for continuous temperature sensing
    Preheating: not required
    Protection tube: oxidised chromium steel type SS 446 / DIN 1.4749
    Element: type K (NiCr/Ni) CLASS 1, max. tolerance 0,4 %.
    Also available with Certificate of Conformity.
    Types: type 501-T-8-"Y" for 8" / 203 mm tip with wire lengths from 31" / 790 mm up to 120" / 3050 mm
      type 701-T-"X"-"Y" for tips from 12" / 305 mm up to 48" / 1220 mm with wire lengths from 31" / 790 mm up to 120" / 3050 mm
      type MT- "X"-6 for tips from 12" / 305 mm up to 48" / 1220 mm with a wire length of 6" / 150 mm , (please see enclosed list with all standard dimensions in inch + metric system)
    view info on MT-models here
    Colour-code: green (+), white (-)
    Connection tube: the element is fixed in lance with one screw
    Connection element: two U-clips at the end of the wire
    MT-versions are WITHOUT U-clip
    Order quantity: 5 pieces = 1 packing unit
    Order information: EXAMPLE > type 501-T-8-43 = 203 mm tip and 1100 mm wire
        type 701-T-12-55 = 305 mm tip and 1400 mm wire
        type MT-24-6 = 610 mm tip and 150 mm wire
    Accessories: EXAMPLE > type 501-EX-43 = lance bend version for 1100 mm elements
        type 101-EX-72 = straight lance for 1830 mm elements
        type 501-PG = plastic grip
        type 501-AG = aluminium grip
        Portaprobe = digital temperature device
    click here to view all Marshall Thermocouple types and dimensions
    click here to view all Marshall accessories
    click here to view Marshall MT-models
    Marshall thermocouples in use