the GENUINE! |
 |
|
|
| The ready for use MARSHALL temperature sensor is a combination of a high temperature resistant steel tube, covered with a thin graphite coating and assembled with a thermo wire. The element can be used directly and without pre-heating. |
| |
 |
Class 1 type K (NiCr-Ni) Marshall thermocouples with ceramic insulators, green-white sleeves (according to international colour code for type K) and U-clip.
(see table of all sizes) |
|
| A Marshall thermo-element consists of a chromium-steel tube type SS 446 / DIN 1.4749 and two type K (NiCr/Ni) thermo wires. These elements are simple to connect, very economical and easy to use with the lightweight lance and optional digital pyrometer. |
| |
 |
small tip at the hot end for quick response |
|
| The hot junction is welded into a small diameter tip. Because of the wall thickness of only 3 mm at this sensible point, very quick temperature readings can be made. The solid construction of the assembly guaranties a very good service life. Through this combination of quick response, long service life and low price MARSHALL became the very well reputed market-leader he is today, the best in his class and reported to be superior. |
| |
 |
Marshall thermokoppels met "Fluke" digitale meter en houder |
|
| The advantages of MARSHALL elements are: |
|
| extremely low costs per temperature reading |
| can be used up to 1350º C |
| quick response time due to the thin wall at the hot tip |
| several hundred measurements in aluminium, excellent durability in bronze, brass and copper (-alloys) |
| easy to use and lightweight design |
| excellent resistance to chemical corrosion of molten aluminium and copper (alloys) |
|
| Standard type K class 1 elements according to European standard IEC-584. Upon request all elements can be furnished with a certificate of conformity. |
|
| All accessories, such as grips, lances and pyrometers are available from stock. |
|
| Application: |
Aluminium- and copper (alloys), dip measurements and continuoustemperature sensing for primary aluminium and copper, introughs, (crucible-) furnaces, filter-boxes and many more |
| Max. temperature: |
1300 - 1350° C for dip measurements
850° C for continuous temperature sensing |
| Preheating: |
not required |
| Protection tube: |
oxidised chromium steel type SS 446 / DIN 1.4749 |
| Element: |
type K (NiCr/Ni) CLASS 1, max. tolerance 0,4 %.
Also available with Certificate of Conformity. |
| Types: |
type 501-T-8-"Y" for 8" / 203 mm tip with wire lengths from 31" / 790 mm up to 120" / 3050 mm |
| |
type 701-T-"X"-"Y" for tips from 12" / 305 mm up to 48" / 1220 mm with wire lengths from 31" / 790 mm up to 120" / 3050 mm |
| |
type MT- "X"-6 for tips from 12" / 305 mm up to 48" / 1220 mm with a wire length of 6" / 150 mm , (please see enclosed list with all standard dimensions in inch + metric system)
view info on MT-models here |
| Colour-code: |
green (+), white (-) |
| Connection tube: |
the element is fixed in lance with one screw |
| Connection element: |
two U-clips at the end of the wire
MT-versions are WITHOUT U-clip |
| Order quantity: |
5 pieces = 1 packing unit |
| Order information: |
EXAMPLE > |
type 501-T-8-43 = 203 mm tip and 1100 mm wire |
| |
|
type 701-T-12-55 = 305 mm tip and 1400 mm wire |
| |
|
type MT-24-6 = 610 mm tip and 150 mm wire |
| Accessories: |
EXAMPLE > |
type 501-EX-43 = lance bend version for 1100 mm elements |
| |
|
type 101-EX-72 = straight lance for 1830 mm elements |
| |
|
type 501-PG = plastic grip |
| |
|
type 501-AG = aluminium grip |
| |
|
Portaprobe = digital temperature device |
|
click here to view all Marshall Thermocouple types and dimensions
click here to view all Marshall accessories
click here to view Marshall MT-models |
|
|
|
|
Marshall thermocouples in use |
|